UHCZ-66 Magnetic float level transmitter
+
  • UHCZ-66 Magnetic float level transmitter

UHCZ-66 Magnetic float level transmitter

Zhongyou Leyi focuses on the development of complete processes and the design, manufacture and installation of complete equipment in the fields of natural gas, coalbed methane, shale gas and biogas.

Key words:

Instrumentation

Classification:

Service Hotline:

Contact E-mail:

Product Description

  • Product description
    • Commodity name: UHCZ-66 Magnetic float level transmitter

    Product Overview:

    The UHCZ-66 series magnetic floating ball liquid level transmitter is independently developed and manufactured by our company. It mainly consists of a floating ball, a sensing element (probe), and an electronic chamber (transmission unit). It uses a magnetic levitation ball as the measuring element, and the magnetic levitation ball synchronously couples with the rise of the liquid level to the sensing element. The electronic chamber collects the signal of the sensing element changing with the liquid level and converts it into a 4-20mA current signal for synchronous output. To expand its application range, the 4-20mA current signal output can be overlaid with the HART communication protocol or communicate using the RS485 bus; To achieve remote monitoring and control of liquid level, the instrument head is equipped with an LCD screen for easy on-site observation and display of liquid level.

    Working principle of magnetic float level transmitter:

    During measurement, the circuit unit generates current pulses that propagate downwards along the magnetostrictive wire (waveguide) and generate a circular magnetic field. When the magnetic levitation ball floats up and down with the change of liquid level, due to the presence of a set of permanent magnets inside the floating ball, a magnetic field is generated simultaneously. When the current magnetic field meets the floating ball magnetic field, a "twisted" pulse, also known as a "return" pulse, is generated. The time difference between the "return" pulse and the current pulse is converted into a pulse signal to calculate the actual position of the floating ball and measure the liquid level; The electronic warehouse converts the change in liquid level into a 4-20mA current signal output, which participates in remote transmission, measurement, recording, and control corresponding to the liquid level change.

    Main performance parameters:

    Measurement range: rigid rod ≤ 6m, flexible rod ≤ 20m

    Measurement accuracy: ≤± 1 mm

    Work pressure: 42.0 MPa and below (optional)

    Wetting materials: 316L/304 stainless steel, PVC, TA2, etc;

    Power supply voltage: 12V~32V DC, typical value 24VDC

    Output signal: 4-20mADC/HART/RS485

    Medium density: ≥ 0.5g/cm3

    Boundary density difference: < 0.05g/cm3

    Maximum temperature resistance: ≤ 250 ℃

    Minimum temperature resistance: ≥ -46 ℃

    Medium viscosity: ≤ 1.25cSt

    Explosion proof mark: Explosion proof Ex db II CT6 Gb intrinsically safe Ex ia II CT6 Gb

    Protection level: IP68

    Electrical interface: M20 × 1.5 (F)/NPT1/2 "(F)

    Main features:

    Stable performance, simple appearance, easy wiring, convenient and fast disassembly and maintenance; The circuit board is equipped with a temperature and pressure compensation function circuit to ensure measurement stability, with a resolution of better than ± 0.5m. The installation adopts a flange or matching card sleeve locking structure, which is easy to install, and the probe insertion depth is flexible and adjustable.

     

    Installation diagram:

     

     

    Model designation description

    Serial number Unit names in model specifications Meaning

    1

    UHCZ -66

     

    Magnetic float level transmitter

     

    2

     

    Y

     

    Measure liquid level

    J

     

    Measurement boundary

    T

     

    Measure the boundary position and liquid level (double float)

    3

     

     

    Y

     

    The probe adopts a hard rod

    R

     

    The probe adopts a soft rod

     

    4

     

     

     

    B

     

    Stainless steel (specify material when ordering)

    F

     

    PTFE lining

    V

     

    PVC (polyvinyl chloride) limit PN1.0MPa

     

     

     

     

     

     

    5

     

     

     

     

    1.0

     

    PN 1.0MPa

    1.6

     

    PN 1.6MPa

    2.5

     

    PN 2.5MPa

    4.0

     

    PN 4.0MPa

    6.3

     

    PN 6.3MPa

    10.0

     

    PN 10.0MPa

    16.0

     

    PN 16.0MPa

    25.0

     

    PN 25.0MPa

    32.0

     

    PN 32.0MPa

    42.0

     

    PN 42.0MPa

    6

     

     

     

     

     

    dc

     

    24VDC

    ac

     

    220VAC 50Hz

    7

     

     

     

     

     

     

    g

     

    Medium density g/cm ³, users can fill in according to the medium themselves

     

    8

     

     

     

     

     

     

     

    P

     

    Ordinary type

    i

     

    Intrinsic safety type

    d

     

    Explosion proof type

    9

     

     

     

     

     

     

     

     

    L、DN

     

    Measurement range and flange specifications

     

    10

     

     

     

     

     

     

     

     

     

    Z

    With steam jacket

    D

    Electric heat tracing

    S

    Equipped with anti frost glass

    UHCZ -66

    Y

    Y

    B

    16.0

    dc

    0.7

    d

    1700

    DN150

    D

    Magnetic floating ball liquid level transmitter, liquid level measurement, hard rod, stainless steel, PN16 OMPa, 24VDC, medium density 0.7g/cm ³, explosion-proof type, measurement range 1700mm, flange specification DN150, with live heat tracing.

    Note: It is recommended to use M20x1.5 (F)/NPT1/2 "(F) for the electrical interface of the magnetic float level transmitter, G3/4" (F) for the electrical interface of the electric tracing, and ZG1/2 "(F) for the steam jacket connection pipe interface.

     

    Ordering Notice (Please provide the following technical parameters when placing an order)

    1) Product Name and Model

    2) Measurement range

    3)Up and down connection flange diameter, pressure rating, flange standard

    4)Type, density, and temperature of working medium

    5)Working environment, ambient temperature

    6)Other requirements (such as installation space, heat tracing insulation, electrical interfaces, output signals, etc.)

      

The product is constantly improved and the configuration parameters are constantly updated. We reserve the right to change the design and parameters without informing the user; the configuration and appearance of the product are subject to the actual product.

Product inquiry

Related Products

Products

Valves

Instrumentation

Honors

Successful case

Enterprise strength

Copyright©2024 Sichuan Zhongyou Leyi Energy Equipment Manufacturing Co., Ltd.

Website construction:China Enterprise Power Chengdu two points

Pay Attention to Leyi

Enterprise Customer Service

SAF Coolest v1.3.1.2 设置面板RUISD-ZDHA-OASFE-ZQQ

图片ALT信息: Sichuan Zhongyou Leyi Energy Equipment Manufacturing Co., Ltd.

无数据提示

Achievement of core technology, cohesion value recognition, tailor-made product solutions for customers

You can view other columns or returnHome Page

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用