Electric float level (boundary) transmitter
+
  • Electric float level (boundary) transmitter

Electric float level (boundary) transmitter

Zhongyou Leyi focuses on the development of complete processes and the design, manufacture and installation of complete equipment in the fields of natural gas, coalbed methane, shale gas and biogas.

Key words:

Instrumentation

Classification:

Service Hotline:

Contact E-mail:

Product Description

  • Product description
    • Commodity name: Electric float level (boundary) transmitter

    Overview

    HL3010 series intelligent electric float liquid level (boundary) transmitter is assembled by introducing the original FIELDVUE DLC3000 series intelligent liquid level controller from Fisher Control Equipment Company of the United States. The instrument can be used to measure liquid level, boundary level or density, can output 4~20mA standard DC signal, and the DLC3000 series intelligent level controller using the HART communication protocol can also access information critical to process operation. With the HART communicator Type 275, which is compatible with the DLC3000 series of intelligent level controllers, information from the process, the intelligent level controller or the pontoon measuring chamber can be acquired. The HART communicator can be connected to the field junction box of the intelligent level controller. Thanks to the HART communicator, the user can query, configure, calibrate or test the intelligent leveler. With the HART protocol, information from the field can be downloaded to the control system or accepted as a single loop.

    HL3010 series intelligent pontoon level (boundary) transmitter is composed of imported DLC3000 intelligent liquid level controller, pontoon measuring room, measuring mechanism, pontoon, torsion tube, etc. The pontoon is submerged in the level in the measuring chamber. Rigid connection with torsion tube system. The force experienced by the torsion tube system is the net value of the pontoon itself minus the liquid buoyancy experienced by the pontoon, and the torsion tube twists at a certain angle under the action of this resultant force. A change in the position, density, or boundary height of the liquid to be measured causes a change in the position of the pontoon, which is transmitted to the torsion tube assembly, causing it to rotate. The rotational motion of the torsion tube is transmitted to the lever of the intelligent level controller, which displaces the magnet fixed to the lever assembly, changing the magnetic field detected by the Hall effect sensor. The sensor converts the magnetic field signal into an electrical signal. DLC3000 series of intelligent level controllers, color microcontrollers and associated electronic circuits measure process variables, provide current output, drive liquid crystal displays (LCDs), and provide HART communication capabilities. The microcontroller receives the ambient temperature compensated and linearized signal, and also compensates for the change in liquid density caused by the temperature change in the thousand process. The digital/analog (D/A) output line accepts the output of the microcontroller and provides a 4-20mA current output signal. The LCD displays the analog output, process variables (level, cut-off level, or density), process temperature (if RTD is installed), torque tube rotation angle, and the percentage range of displayed variables.

    Main technical indicators

    Measuring range:

    0~350,500,750,1000,1200,l500,1800,2000,2500,3000mm

    Reference accuracy: ±0.5%FS, ±0.1%FS

    Independent linearity: ±0.5%FS

    Hysteresis: <0.2%FS (only for DLC3000 DLC3000 digital level controller).

    Repeatabilhy: ± 0.1% FS (only for DLC3000 level control

    only for DLC3000 level controller).

    Dead zone: < 0.2%FS (only for DLC3000 DLC3000 level controller).

    Power supply: 12V~30VDC; With reversed polarity protection

    Output signal:

    Analog analog: 4~20mADC (positive direct action).

    20~4mADC (reverse action).

    Digital: HART 1200 baud frequency-shift keying (FsK).

    Liquid crystal display LCD: analog quantity or liquid level, boundary level, temperature, torque tube angle and percentage range

    ★ Measuring chamber material and operating temperature:

     

    Zhongyou

     

    Minimun density difference: 0.05g/cm3

    Operating influences:

    power supply effect: When the voltage changes between the minimum and maximum values of the specified voltage, the output changes <± 0.2%FS

    Temperature effect: When the operating temperature changes within -40~80°C, the output changes <± 0.03%FS/°C

    Alarmjumper: DLC3000 can self-diagnose and configure high and low alarms to display process variables. When a high or low alarm or a fault is detected, the analog output signal will show less than 4mA or higher than 20mA, and the meter is generally placed on the high position when the meter leaves the factory.

    In breaking protection:

    Electrical connection: 2 l/2-14NPT female threads, one at the bottom and the other in front of the junction box. M20 adapters are available.

    ★ Ambient Temperature and Humidity:

     

    Zhongyou

     

    Zhongyou

    Notes:

    1. The electrical installation must be correct to prevent errors caused by electrical noise, and shielded cables should be used

    2. Ordinary copper wire jumper wiring with sufficient cross-sectional area is used to ensure that the voltage of the liquid level controller terminal is not lower than 12.0V

    3. The signal line does not need to use shielded wire, but in order to get the best effect, it is recommended to use twisted pair.

     

    Zhongyou

     

    Markup Example: HL30l0-H2H162EKl-1000

    HL3010 electric float level transmitter with HART communication protocol, made of lCrl8Ni9Ti stainless steel, mounted on the side of the outer float. Liquid level measurement, working pressure 613MPa, medium temperature 320°C, intrinsically safe type, with steam jacket, heat tracing connection Gl/2", measuring range 1000mm.

    ZhongyouZhongyou

The product is constantly improved and the configuration parameters are constantly updated. We reserve the right to change the design and parameters without informing the user; the configuration and appearance of the product are subject to the actual product.

Product inquiry

Related Products

Products

Valves

Instrumentation

Honors

Successful case

Enterprise strength

Copyright©2024 Sichuan Zhongyou Leyi Energy Equipment Manufacturing Co., Ltd.

Website construction:China Enterprise Power Chengdu two points

Pay Attention to Leyi

Enterprise Customer Service

SAF Coolest v1.3.1.2 设置面板RUISD-ZDHA-OASFE-ZQQ

图片ALT信息: Sichuan Zhongyou Leyi Energy Equipment Manufacturing Co., Ltd.

无数据提示

Achievement of core technology, cohesion value recognition, tailor-made product solutions for customers

You can view other columns or returnHome Page

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用