UHCZ-66 Flip-Plate Magnetic Float Level Gauge
+
  • UHCZ-66 Flip-Plate Magnetic Float Level Gauge

UHCZ-66 Flip-Plate Magnetic Float Level Gauge

Zhongyou Leyi focuses on the development of complete processes and the design, manufacture and installation of complete equipment in the fields of natural gas, coalbed methane, shale gas and biogas.

Key words:

Classification:

Service Hotline:

Contact E-mail:

Product Description

  • 产品描述
    • Commodity name: UHCZ-66 Flip-Plate Magnetic Float Level Gauge

    Product Overview:

      The UHCZ-66 flip-float magnetic level gauge uses a magnetic float as the sensing element. Through magnetic coupling via magnets, changes in the liquid level are synchronously transmitted to the magnetic flip-flap display panel, providing an intuitive and clear indication of the liquid level position. This level gauge is suitable for measuring the liquid level and interface of various media in pressurized or open containers such as tanks and spherical tanks of all types. Equipped with explosion-proof features, this level gauge can be used in hazardous environments involving corrosive, toxic, flammable, and explosive substances. To further expand its application scope, it can be equipped—with compliance to relevant standards and requirements—with level switches and remote transmission devices, enabling it to output multiple electrical signals. Among these, switch signals and 4–20 mA DC current signals for remote transmission are particularly common. The gauge can also support the HART communication protocol or use RS485 bus communication. The switch signals from the level switch can be utilized for alarm generation or level control, while the remote transmission signal converts changes in the liquid level into a standard 4–20 mA DC current signal that is transmitted to the control room, thereby enabling remote monitoring and control of the liquid level.

     

    Working principle:

      The flip-plate magnetic float level gauge is a specialized device developed and designed by ingeniously combining the principles of magnetic coupling, Archimedes' buoyancy law, and the principle of communicating vessels. It is used exclusively for measuring liquid levels and interface positions. The main body of the level gauge is installed on the vessel via upper and lower connecting flanges, forming a communicating vessel system with the container. As a result, the liquid level inside the main body of the level gauge is exactly the same as the liquid level inside the container, causing the magnetic float inside the main body to rise and fall along with the liquid level in the container. Since we cannot directly see the liquid level, we have mounted a magnetic flip-plate display panel on the outer wall of the main body of the level gauge. During the manufacture of the magnetic float, we embed a 360° annular permanent magnet at the boundary between the part of the float that sinks into the liquid and the part that floats on the surface. As the liquid level rises or falls, the magnetic field of the float passes through the main body and acts upon the magnetic flip-plate display panel, causing the flip plates to rotate 180°. Since each flip plate consists of two sides—one red (or yellow) and one white—after a 180° rotation, the side facing outward from the panel will change to the opposite color (red or yellow). The boundary between the two colored sides of the flip plates precisely indicates the height of the liquid level (or interface).

     

    Main performance parameters:

      Measurement range: Any selected value within 0–20 m.

      Measurement accuracy: Remote transmission accuracy ≤ ±1 mm; on-site magnetic flip-plate display accuracy ±5 mm.

      Following speed: ≤0.1 m/s

      Operating temperature: Low-temperature type ≤ -100℃, high-temperature type ≥ 550℃

      Working pressure: ≥42.0 MPa and below (optional)

      Main body and accessory wetted materials: 316L/304 stainless steel, HC, TA2, PVC, etc.

      Float sensor materials: 316L/304 stainless steel, TA2, TA18, PVC, etc.

      Medium density: The measurable medium density is ≥0.45 g/cm³. The density difference between media is ≥0.2 g/cm³.

      Medium viscosity: ≤1.25 St

      Explosion-proof rating: Flameproof type Ex db IIC T6 Gb, Intrinsically safe type Ex ia IIC T6 Gb

      Protection rating: IP67

      Supply voltage: 12V~30V DC, typical value 24V DC, with lightning protection, reverse connection protection, and overcurrent protection features.

      Output level remote transmission signal: 4–20 mA DC / HART7 / RS485

      Output level switch signal: NO/NC/SPDT/DPDT

      Electrical interface: M20×1.5(F)/NPT 1/2″(F)

     

    Main features:

      The product features stable performance, a simple and intuitive design, easy installation, and convenient and quick disassembly, assembly, and maintenance. Its accompanying electrical remote transmission design incorporates an EMC-compatible circuit that meets the requirements of GB/T17626.2-2018, achieving Test Level 3 for electrostatic discharge immunity; it also complies with Test Level 3 under GB/T17626.5-2019 for surge (impulse) immunity; passes the Test Level 3 under GB/T17626.4-2018 for electrical fast transient/burst immunity; and meets Test Level 4 under GB/T17626.8-2006 for power-frequency magnetic field immunity. The product has obtained SIL2 certification and includes built-in temperature and pressure compensation functions to ensure measurement stability.

     

    Installation diagram:

     

    Model Coding Instructions

    Serial number

    Unit name in model specifications

    Meaning

    1

    UHCZ

     

    Flip-plate magnetic float level gauge

    2  

    66

     

    Magnetic coupling

    3

     

     

     

     

     

     

    S

     

    Side-mounted field indication

    T

     

    Top-mounted field indication

    4

         

    Y

     

    Liquid level measurement
    J

     

    Interface measurement
    5        

    B

      Stainless steel (specify the exact material when placing the order)
    F   Polytetrafluoroethylene lining

    V

      PVC (Polyvinyl Chloride) PN 1.0 MPa
    6          

    1.0

      PN 1.0 MPa

    1.6

      PN 1.6 MPa

    2.5

      PN 2.5 MPa

    4.0

      PN 4.0 MPa

    6.3

      PN 6.3 MPa

    10.0

      PN 10.0 MPa
    16.0   PN 16.0 MPa

    25.0

      PN 25.0 MPa

    32.0

      PN 32.0 MPa

    42.0

      PN 42.0 MPa
    7            

    D

      Without alarm switch
    A   Bring the alarm switch.
    B   Underflow alarm switch

    C

      With upper and lower alarm switches
    8               DC   24VDC
    AC   220V AC 50Hz
    9                

    W

      Non-transmitter transducer

    You

      There is a remote transmission transmitter; technical parameters should be specified in writing when placing the order.
    10                   g   Medium density: g/cm³—User enters based on the medium.
    11                     P   Standard type
    I   Intrinsically safe
    d   Flameproof type
    12                       L, DN Measure the center distance and flange specifications.
    13                         Z With steam jacket
    D Electrically Heated
    S With frost-proof glass

    Selection Example

    UHCZ-

    66

    S

    Y

    F

    4.0

    C

    DC

    You

    0.7

    d

    1700 DN20

    Z

    Flip-plate magnetic float level gauge, side-mounted, for liquid level measurement, with PTFE lining, PN 4.0 MPa, equipped with upper and lower limit alarm switches, 24VDC, featuring a remote transmitter, medium density of 0.7 g/cm³, explosion-proof design, measuring center distance of 1700 mm, flange specification DN20, and equipped with a steam jacket.

      Note: For the liquid-level switch and remote transmitter for liquid-level measurement, it is recommended to use an M20x1.5(F) electrical interface. For electric heating cables, the recommended electrical interface is G3/4″(F). For steam-jacketed pipe connections, the recommended interface is ZG1/2″(F).

       Ordering Instructions (Please provide the following technical parameters when placing your order)

      (1) Product name and model

      (2) Measurement range

      (3) Flange pipe diameter, pressure rating, and flange standard for top and bottom connections

      (4) Types, density, and temperature of the working medium

      (5) Working environment, ambient temperature

      (6) Other requirements (e.g., installation space, trace heating and insulation, electrical interfaces, output signals, etc.)

The product is constantly improved and the configuration parameters are constantly updated. We reserve the right to change the design and parameters without informing the user; the configuration and appearance of the product are subject to the actual product.

Product inquiry

Related Products

Products

Valves

Instrumentation

Honors

Successful case

Enterprise strength

Copyright©2024 Sichuan Zhongyou Leyi Energy Equipment Manufacturing Co., Ltd.

Website construction:China Enterprise Power Chengdu two points

Pay Attention to Leyi

Enterprise Customer Service

SAF Coolest v1.3.1.2 设置面板RUISD-ZDHA-OASFE-ZQQ

图片ALT信息: Sichuan Zhongyou Leyi Energy Equipment Manufacturing Co., Ltd.

无数据提示

Achievement of core technology, cohesion value recognition, tailor-made product solutions for customers

You can view other columns or returnHome Page

V1.3.1 SVG图标库请自行添加图标,用div包起来,并命名使用